Evacuation diagrams Melbourne workplaces use should help employees, visitors and contractors identify emergency exits, evacuation routes and essential fire safety equipment. Each diagram needs to reflect the building’s current layout, show accurate information and be positioned where occupants can easily see it.
Office renovations, tenancy changes and relocated safety equipment can make existing diagrams inaccurate. A diagram showing an outdated floor plan or incorrect exit location may confuse occupants when clear evacuation information matters most.
Australian Standard AS 3745:2010, Planning for emergencies in facilities, provides a framework for evacuation diagram content, positioning and orientation. Melbourne workplaces must also consider their applicable Victorian occupational health and safety obligations.
This guide explains what workplace evacuation diagrams should include, where they should be displayed, seven common mistakes to avoid and how professional evacuation diagram preparation works.
What Are Workplace Evacuation Diagrams?
An evacuation diagram is a visual representation of a building or facility showing information occupants need to understand their surroundings and evacuate during an emergency.
Unlike a general floor plan, an evacuation diagram highlights emergency exits, evacuation routes, firefighting equipment, emergency communication points and assembly arrangements.
A well-prepared diagram helps someone unfamiliar with the building identify their current position and locate relevant emergency information.
Evacuation diagrams are commonly used in:
- Commercial offices and multi-tenanted buildings
- Retail shops and shopping centres
- Warehouses and manufacturing facilities
- Schools and educational facilities
- Healthcare and aged-care buildings
- Hotels and accommodation properties
- Other workplaces where emergency evacuation planning is required
The number, content and placement of diagrams should reflect the facility’s layout, occupancy and emergency arrangements.
A diagram suitable for a small office may not provide enough information for a multi-level commercial property.
Evacuation Diagram Requirements in Melbourne: AS 3745
Australian Standard AS 3745:2010, Planning for emergencies in facilities, provides a recognised framework for emergency preparedness, including evacuation diagrams.
Section 3.5 addresses diagram content, number, location, positioning and orientation.
The standard includes both requirements and recommendations. Its application to an individual Victorian workplace should be assessed alongside relevant legal obligations and facility-specific circumstances.
In Victoria, employers have responsibilities under occupational health and safety legislation to manage workplace risks and prepare for foreseeable emergencies.
WorkSafe Victoria’s workplace emergency guidance recommends considering evacuation procedures, trained wardens, emergency service arrangements and regular evacuation exercises.
Building owners, employers and facility managers should also consider relevant building approvals, occupancy arrangements, industry requirements and emergency management procedures.
What Information Should an Evacuation Diagram Include?
AS 3745 identifies information for evacuation diagrams prepared in accordance with its provisions.
Key elements include:
- Diagram identification: A clear ‘EVACUATION DIAGRAM’ title.
- Current location: A visible ‘YOU ARE HERE’ marker identifying the viewer’s position.
- Floor layout: A representation of the relevant building level or area.
- Emergency exits: Designated exits identified using appropriate symbols.
- Fire safety equipment: Locations of fire extinguishers, hose reels, hydrants and fire blankets where installed.
- Emergency communication points: Relevant alarm activation points and communication equipment where provided.
- Assembly information: The designated assembly area or areas.
- Legend: An explanation of the symbols appearing on the diagram.
- Validity date: Information identifying the diagram’s validity.
The standard also addresses other relevant features, such as fire indicator panels and refuges where applicable.
Depending on the facility, additional information may be appropriate.
The aim is to present the necessary emergency details clearly without making the diagram difficult to interpret.
Where evacuation instructions or assembly arrangements appear, they should be consistent with the building’s emergency management plan.
Are All Evacuation Diagrams the Same?
No. Evacuation diagrams should be prepared for the particular building and the location where they will be displayed.
For example, a diagram near an office reception area may require a different ‘YOU ARE HERE’ marker and orientation from one installed in a warehouse corridor.
Multi-level buildings may also require separate diagrams for different floors or areas.
Using the same generic diagram throughout a large facility can make it difficult for occupants to identify their location and understand which evacuation routes are available.
Each installed diagram should reflect its position and the surrounding building layout.
Where Should Evacuation Diagrams Be Displayed?
Evacuation diagrams should be placed where occupants and visitors can readily view and understand them.
Under AS 3745, the facility’s Emergency Planning Committee (EPC) determines the number and locations of diagrams.
Suitable locations may include:
- Main building entrances and reception areas
- Corridors and common access areas
- Lift lobbies and circulation spaces
- Shared staff areas
- Areas where occupants and visitors can readily access emergency information
The appropriate positions depend on the facility’s layout, occupancy and evacuation arrangements.
For example, a diagram installed behind furniture or in an obstructed corridor may be difficult to locate when someone needs emergency information.
Property managers should consider visibility, accessibility and the suitability of each proposed position before installation.
Evacuation Diagram Mounting Height and Orientation
AS 3745:2010 recommends positioning evacuation diagrams within a zone between 1,200 mm and 1,600 mm above the finished floor.
This is expressed as a recommendation within the standard. The applicable positioning details and any additional requirements should be checked before installation.
Correct orientation is equally important.
A diagram should correspond with the viewer’s physical surroundings so that the direction of exits and routes is easy to understand.
For example, if a corridor extends to the right of someone facing the diagram, the illustrated layout should represent that direction accurately.
Installing identical diagrams on opposite sides of a corridor without adjusting their orientation may confuse occupants.
Property managers should check orientation at every installation point rather than assuming one diagram arrangement will suit multiple locations.
Seven Common Evacuation Diagram Mistakes in Melbourne Workplaces
Even workplaces with existing evacuation diagrams can have problems affecting their accuracy or usefulness.
The following seven issues are worth checking during routine building inspections and emergency planning reviews.
1. Using Outdated Floor Plans
Office renovations, new partitions, relocated doors and tenancy changes can alter evacuation arrangements.
A diagram based on an old floor plan may show a route that is no longer accessible or fail to identify a new exit.
Recommended action: Review evacuation diagrams whenever changes affect the building layout, escape routes or relevant emergency equipment.
2. Incorrect ‘YOU ARE HERE’ Locations
The ‘YOU ARE HERE’ marker helps occupants identify their position within the building.
If the marker is inaccurate, employees or visitors may misunderstand where they are in relation to emergency exits.
This can happen when diagrams are relocated or reused without checking their new installation positions.
Recommended action: Verify the marker on each diagram against its actual installed location.
3. Incorrect Diagram Orientation
A diagram may show the correct floor layout but still be difficult to interpret if it is rotated incorrectly.
This is particularly relevant where similar diagrams are installed on opposite sides of a corridor.
Recommended action: Check that each diagram’s orientation corresponds with the viewer’s surroundings and intended direction of travel.
4. Missing or Incorrect Fire Equipment Locations
Fire extinguishers, hose reels, alarm points and other emergency equipment may be relocated during building works or operational changes.
If diagrams still show the previous locations, occupants may receive inaccurate information.
Recommended action: Confirm relevant equipment locations during diagram preparation and update affected information after changes.
5. Poor Visibility or Placement
Diagrams placed behind furniture, in obstructed areas or where they are difficult to see may not provide useful information when needed.
Even a technically accurate diagram has limited value if occupants cannot locate or read it.
Recommended action: Choose visible, accessible positions and check that diagrams remain unobstructed during routine inspections.
6. Including Too Much Information
Excessive text, unnecessary symbols and complicated layouts can make evacuation diagrams harder to interpret.
The diagram should communicate the required emergency information clearly without unnecessary visual clutter.
Recommended action: Follow the applicable content requirements, use a clear legend and include optional information only where it helps occupants.
7. Failing to Review Diagrams
Evacuation diagrams may remain displayed long after the building’s layout or emergency arrangements have changed.
Without regular checks, inaccuracies can go unnoticed.
Recommended action: Include diagram reviews in the facility’s emergency planning process and arrange updates when relevant changes occur.
Evacuation Diagram Review Checklist for Property Managers
Property managers can use the following checklist to identify common issues before arranging a detailed assessment.
| Inspection Item | What to Check | Recommended Action |
| Floor layout | Does the diagram match the current building layout? | Update drawings after relevant changes |
| ‘YOU ARE HERE’ marker | Does the marker match the installation position? | Correct inaccurate location markers |
| Orientation | Does the diagram correspond with the viewer’s surroundings? | Verify orientation at each installation point |
| Emergency exits | Are designated exits correctly represented? | Check against current evacuation arrangements |
| Fire equipment | Are relevant equipment locations accurate? | Update affected symbols and locations |
| Assembly information | Does the diagram reflect the emergency plan? | Confirm with responsible personnel |
| Visibility | Can occupants easily locate and read the diagram? | Review placement and remove obstructions |
| Validity date | Does the diagram represent the current approved version? | Review and update documentation where needed |
This checklist is a starting point rather than a complete compliance assessment.
A full review should consider the applicable provisions of AS 3745 and any additional obligations affecting the facility.
When Should Workplace Evacuation Diagrams Be Updated?
Evacuation diagrams should be reviewed as part of the facility’s emergency planning arrangements and whenever changes affect the information displayed.
Common reasons for a review include:
- Building renovations or changes to internal layouts
- Changes to emergency exits or evacuation routes
- Relocation of firefighting or emergency communication equipment
- Changes to designated assembly areas
- Updates to emergency management procedures
- Changes in occupancy or building use that affect evacuation arrangements
AS 3745 addresses the ongoing maintenance and review of emergency planning documentation. The applicable review requirements should be checked against the standard and relevant regulatory obligations.
Property managers should also maintain records of approved diagram versions and updates.
This is particularly useful in multi-tenanted buildings where changes to individual workplaces may affect shared evacuation arrangements.
Keeping accurate version records makes it easier to identify which diagrams need updating and confirm that current information is displayed.
Professional Evacuation Diagram Design: What Does the Process Involve?
Professional evacuation diagram design involves translating building plans and emergency information into clear, site-specific diagrams.
Australian Fire Protection provides evacuation diagram design services for Australian businesses, including remote preparation using client-supplied building information.
The company’s process includes gathering building details, preparing drafts, obtaining client approval and producing final diagrams.
Step 1: Gathering Building Information
The design team reviews available floor plans, site layouts or sketches to understand the facility.
Relevant details may include emergency exits, firefighting equipment, assembly arrangements and proposed diagram locations.
Where additional information is needed, the layout and emergency equipment positions must be checked.
Australian Fire Protection offers remote preparation where clients can provide suitable building information without a site visit.
Step 2: Preparing the Draft Diagrams
The drafting team uses CAD or specialised mapping software to prepare diagrams showing the relevant floor layout, emergency exits, equipment and evacuation information.
Individual diagrams can be adapted to their proposed installation locations.
This helps ensure the ‘YOU ARE HERE’ marker and orientation suit each display position.
Step 3: Client Review and Approval
Draft diagrams are supplied to the client for review before final production.
This allows building details, equipment locations, assembly information and other relevant features to be checked.
Any necessary amendments can then be made before approval.
Accurate client verification is particularly important when diagrams are prepared remotely.
Step 4: Producing the Final Diagrams
Australian Fire Protection offers evacuation diagrams in A3 and A4 formats, with laminated finishes and other presentation options.
A digital PDF master file is also provided for record-keeping.
The appropriate format should reflect the diagram’s content, proposed installation position and applicable requirements.
Step 5: Installation and Final Checks
Approved diagrams are installed in their designated positions.
Australian Fire Protection advertises installation services, while clients may also arrange installation themselves.
Melbourne businesses should confirm whether on-site installation is available for their location before proceeding.
After installation, each diagram should be checked for:
- Correct position and visibility
- Accurate ‘YOU ARE HERE’ location
- Correct orientation
- Consistency with the approved design
- Appropriate mounting and presentation
For more information, visit Australian Fire Protection’s Evacuation Diagrams service page.
Evacuation Diagrams and Emergency Management Plans: How Do They Work Together?
Evacuation diagrams form part of a broader workplace emergency preparedness system.
An emergency management plan explains how an organisation prepares for emergencies, allocates responsibilities and establishes response procedures.
Evacuation diagrams support these arrangements by showing occupants relevant building information.
For example, if an emergency management plan identifies a particular assembly area, the diagrams showing assembly information should reflect the same arrangement.
Similarly, if evacuation routes or emergency procedures change, associated diagrams may also need updating.
Maintaining consistency between the plan and diagrams helps occupants receive clear information during an emergency.
Businesses reviewing their workplace emergency arrangements can explore Australian Fire Protection’s emergency planning and PlanSafe services.
Australian Fire Protection’s Evacuation Diagram Design Services
Australian Fire Protection has provided evacuation diagram and workplace fire safety services for more than 30 years.
Its advertised evacuation diagram services include:
- Preparation of diagrams for commercial and other facilities
- In-house design using CAD and specialised mapping software
- On-site information gathering where arranged
- Remote diagram preparation using client-supplied plans and information
- Client review and approval before production
- Printed diagram options and digital PDF master files
- Optional installation arrangements
The business works with a range of facilities, including offices, schools, retail premises, healthcare environments and industrial workplaces.
For Melbourne businesses, remote diagram preparation may be suitable where accurate floor plans and verified site information are available.
Clients should confirm whether an on-site assessment is needed and whether installation or other location-specific services can be arranged for their property.
Frequently Asked Questions
Are Evacuation Diagrams Required in Melbourne Workplaces?
AS 3745:2010 contains provisions for displaying evacuation diagrams in facilities.
Employers and building managers should assess these provisions alongside applicable Victorian workplace safety legislation, building requirements and any industry-specific obligations.
The requirements for an individual workplace depend on its circumstances.
Can I Create My Own Workplace Evacuation Diagram?
A workplace can prepare its own diagrams if it has the appropriate expertise and can meet the applicable requirements.
Professional preparation may help where buildings have complex layouts, multiple floors or limited access to accurate building drawings.
Regardless of who prepares the diagrams, their content, placement and orientation need to be correct.
How Many Evacuation Diagrams Does a Building Need?
The appropriate number depends on the facility’s layout, size, occupancy and emergency arrangements.
Under AS 3745, the Emergency Planning Committee determines the number and locations of evacuation diagrams.
What Size Should an Evacuation Diagram Be?
AS 3745 specifies minimum diagram dimensions according to the information displayed.
A4 and A3 are commonly used formats, but the appropriate size depends on the diagram’s content and configuration.
The relevant dimensional requirements should be checked before final production.
Do Evacuation Diagrams Need to Be Installed Professionally?
The main consideration is whether the diagrams are installed correctly and meet applicable positioning, visibility and orientation requirements.
Australian Fire Protection offers installation as an option and also supplies diagrams for client-managed installation.
Melbourne businesses should confirm local installation availability when requesting a quote.
Can Evacuation Diagrams Be Designed Remotely?
Yes. Australian Fire Protection offers remote evacuation diagram preparation using building plans, sketches and other information supplied by clients.
Accurate building details and client verification are essential to this process.
How Long Does Professional Evacuation Diagram Design Take?
Australian Fire Protection advertises a typical preparation period of approximately two to four weeks, depending on project complexity and urgency.
Project-specific timeframes should be confirmed when requesting a quote.
Arrange Evacuation Diagram Design for Your Melbourne Workplace
Evacuation diagrams should reflect the building’s current layout, communicate relevant emergency information and be correctly positioned for occupants.
If your Melbourne workplace has undergone renovations, tenancy changes or updates to emergency equipment, it may be time to review the existing diagrams.
Australian Fire Protection provides evacuation diagram design services, including remote preparation, client review, printed diagrams and optional installation arrangements.
Need new or updated evacuation diagrams for your Melbourne workplace?
Contact Australian Fire Protection to discuss your building layout, diagram requirements, remote design options and service availability.